FTTH Indoor/outdoor Fiber Optic Cable Simplex double Jacket 1 core

FTTH Indoor/outdoor Fiber Optic Cable Simplex double Jacket 1 core
FTTH Indoor/outdoor Fiber Optic Cable Simplex double Jacket 1 coreFTTH Indoor/outdoor Fiber Optic Cable Simplex double Jacket 1 coreFTTH Indoor/outdoor Fiber Optic Cable Simplex double Jacket 1 core
CategoriesIndoor distribution cable
BrandRUX
ModelGJFJH
Fiber Count1 core
OEMAvailable
ApplicationFTTH
FOB portShenzhen
Terms of PaymentL/C, Western Union, MoneyGram, T/T
Download DOCpdf icon
Update TimeMar 29,2024
Detail Information
1.1    CableStructure(FTTH Indoor/outdoor Fiber Optic Cable)
ruxfiber

1.2     Characteristics

A.   Tight buffer fiber easystrip

B.   Tight buffer fiber has excellent flame-retardant performance

C.   Aramid yarn as strengthmember make cable have excellent tensile strength

D.   The jacketanti-corrosion, anti-water, anti-ultraviolet radiation, flame-retardant andharmless to environment etc.

 

1.3     Cable Application

A.   Optical fiber jumper or pigtail

B.   Indoor riser level andplenum level cable distribution

C.   Interconnect betweeninstruments, communication equipment.

 

1.4   CableProperties

Transporttemperature: - 20 deg C to + 60 deg C

Storage Temperature: - 20 deg C to + 60 deg C

Operating temperature: - 20 deg C to + 60 deg C

Installation temperature: - 5 deg C to + 50 deg C


2. Optical Characteristics& Technical Parameters 

2.1 Technical Parameters

Cable Code
Cable Diameter
mm
Cable Weight(Ref)
kg/km
TBF Diameter
μm
Tensile strength
Long/Short term
mm
Crush Resistance
Long/short term
N/100mm
Bending Radius
Dynamic/Static
mm
PVC jacket
LSZH jacket
GJFJH
2.6
8
10
600±50
100/300
200/600
60/30
GJFJH
2.9±0.2
15
18
900±50
200/500
200/600
60/30
GJFJVH
3.8±0.2
30
35
900±50
200/500
200/600
60/30
2.2 Optical Characteristics
Fiber Type
Attenuation
OFL
Valid mode
band width
10G Ethernet
 link length SX
Min. bending
 radius
Condition
1310/1550nm
850/1300nm
850/1300nm
850nm
850nm
Typical
Max.
Typical
Max.



Unit
dB/km
dB/km
dB/km
dB/km
MHZ.km
MHZ.km
m
mm
G652D
0.36/0.22
0.5/0.4





16
G657A1
0.36/0.22
0.5/0.4
10
G657A2
0.36/0.22
0.5/0.4
7.5
OM1
3.0/1.0
3.5/1.5
500/500
2000
300
30
OM2
3.0/1.0
3.5/1.5
200/500
4700
550
30
OM3
3.0/1.0
3.5/1.5
1500/500
2000
300
30
OM4
3.0/1.0
3.5/1.5
3500/500
4700
350
30

3. Packing and shipping

 

3.1  The cables are packed in wooden drums andthen in carton box

3.2  Standard delivery length is 1km/roll or percustomer’s requirements.

3.3  Sheath Marking

The sheath marking are hotstamped on the sheath at one meter interval with white color. The accuracy ofthe length marking shall be 0 ~ +1%.

Re-marking is yellow color, ifnecessary.

RUX  ***  xxFIBRE  Month/Year  XXXXM

l RUX: Manufacturer’s Name

l ***: Customer’s name

l xxFIBRE: Fiber count

l Month/Year: Manufacturedate

l XXXXM: The figure of meter.